If you are experiencing issues with pump operation with the SV controller, it may be an indication that the TYPE value
has been corrupted. Please follow the instructions below to check this value is set correctly.
1. To access the configuration menu, power on the SV series controller. Simultaneously press and hold: Blower, W.CLN & Pump B buttons together until either [V.PMP] or [BRND] appears on the display
or
2. Press the UP button until the [TYPE] menu is displayed. Press OK to enter [TYPE] menu option
3. Use the UP or DOWN buttons to navigate to the correct model number (this should typically match the model number of the touchpad or controller underneath the spa)
5. Press OK to confrm and save new setting. [TYPE] will be displayed on the screen
6. Press the UP button until the display shows [BOOT]
7. Press OK and the system will restart.