Tech Note – Changing Sanitisation (O3/UV) Operation
The SV controller has the ability to change how the sanitiser power outlet operates during manual use by adjusting the “SANI” function.
ON Sanitiser operates while pool is in sue
OFF Sanitiser turns off when pool is in use (default)
SV3-T
Figure 1
SV Series controllers feature a hidden OEM menu which allows the customisation of the controller to suit a wide range of equipment configurations and operation
1. To access the OEM menu, power on the SV series controller
|
|
2. Simultaneously press and hold: Blower & W.CLN buttons together until [C.LMT] appears on the display (fig.1) |
|
3. Press the UP arrow until [SANI] is displayed on the scree (2 up button presses) | |
4. Press OK to enter [SANI] menu option to view the current sanitisation operation mode. |
|
5. Use the UP or DOWN arrows to adjust to the desired setting and press O.K to confrim your selection. The display will return to [SANI] |
|
6. Either wait until the screen times out and returns to the temperature or use the DOWN arrow to navigate to [EXIT] and press OK |