Setting filtration run time
FILT – Total Filtration run time (hours per day)
Total filtration run time per day can be set via the Setup menu. Simply hold down both the UP & DOWN arrow buttons at the same time. Then toggle through the menu options with either arrow button until the screen displays FILT. Press OK, then use the arrow buttons to select the number of hours per day your spa will filter for. Press OK to confirm.
NOTE: All time spent running the pump under normal operation (manual use, water temperature maintenance, sanitisation cycles) will be considered and where required the pump will run for additional periods throughout the day to maintain the minimum level of daily filtration as specified by the user.
F.CYC – Filtration Cycle Blocks
This setting defines the maximum number of hours the spa is allowed to sit still between filtration cycles, during the awake period.
On an SV Mini 1 or SV Mini 2 controller this number is fixed at 3 hours. However, on the premium SV range of controllers it can be adjusted via the setup menu. Hold down both the UP & DOWN arrow buttons at the same time. Then toggle through the menu options with either arrow button until the screen displays F.CYC. Press OK, then use the arrow buttons to select the number of hours between filtration blocks. Press OK to confirm.
Accessible options in the setup menu
Menu Item | Setting | Notes |
---|---|---|
MODE | Operating Mode | Normal / Away / Week Modes |
FILT | Hours of filtration per day | 1 to 24 hours |
F.CYC | Filtration cycle blocks | Set filtration to run every 1,2,3,4,6,8,12 or 24 hrs |
SNZE | Sleep time menu | |
1.SNZ | Sleep timer 1 | [1.DAY] Days of week, [1.BGN] Begin Time, [1.END] End Time |
2.SNZ | Sleep timer 2 | [2.DAY] Days of week, [2.BGN] Begin Time, [2.END] End Time |
R.SET | Reset sleep timers | Reset sleep timers to factory defaults |
EXIT | Exit sleep time submenu | |
P.SAV | Power save settings | Off, Low (off-peak filtration), High (off-peak filtration & heating) |
W.CLN | Automatic sanitise time | Daily run time of automatic sanitise cycle (00:00 - 23:59) |
D.DIS | Default display mode | Water Temp (W.TMP), Set Temp (S.TMP) or Clock (TIME) |
T.OUT | Load time out period | Pump / Blower time out period (10 to 60 minutes) |
H.PMP | Heat pump operating mode | Auto (heat or cool) / Heat / Cool / Off (heat pump disabled) |
H.ELE | Heat pump with SV element boost | On = Heat pump + SV element combined for heating Off = Heat pump only |
EXIT | Exit setup menu |
Important Notes
The setup menu item settings are stored in non-volatile memory (EEPROM) and are remembered when power is turned off. No need to reprogram settings when power is restored.
A ten (10) second idle menu time out period exists. If a button press is not detected for 10 seconds, the menu will time out and the screen will return to the default display mode.