TYPE setting

TYPE setting The TYPE setting on a SpaNET controller is vital for pump configuration, heating & touchpad functionality. When the TYPE value is set incorrectly it will impact the function of your spa dramatically. Common symptoms are pump buttons functions have changed or are controlling different pumps/blower compared to normal, spa overheating & jet pumps…

Check Vari pump setting (V.PMP)

Check Vari pump setting (V.PMP) Enter the OEM menu by simultaneously pressing and holding: Pump B, Air Blower & Water Clean buttons until “V.PMP” is displayed Press OK to enter the vari pump (V.PMP) menu option and the display should show “ON” If it shos ‘OFF’ press the UP arrow button untill “ON” is displayed…

Viewing Electric Element Amp Draw

Viewing Electric Element Amp Draw Viewing the amperage draw of your SV series electric element is a good indicator to determin whether or not your spa will heat. It’s important to firstly ensure the flame indicator light on your SV sereis touchpad is illuminated RED as this means the spa controller should be sending power…

Heat Pump Icing Up

Heat Pump Icing Up All SV series heat pumps have anit-freeze protection software. If these software vaules are set incorrectly or have corrupted it may cause the condenser to freeze. During colder months it’s usefull to have the defrost cycle kick in earlier & longer to prevent the heat pump icing up. These defrost settings…

SV Series Software (EEPROM) Reset

SV Series Software (EEPROM) Reset The software reset is a good place to start when your spa control begins to behave differently to how you’d expect. Some examples are the temperature displaying in fahrenheit rather than degrees celsius or the heater light not illuminating red when the water temperature is lower than set tetemperature. Performing…

SV Series Heat Pump Error Codes

SV Series Heat Pump Error Codes HEAT PUMP AMB – Ambient temperature sensor error No signal from ambient temperature sensor, or signal is corrupted Check ambient sensor is connected to heat pump pcb Inspect data cable for damage and check data cable connected correctly to SV spa control Disconnect/reconnect data cable from SV spa control…

DIP Switches Explained

DIP Switches Explained Basic spa configuration is achieved by setting dip switches. The dip switches determine pump configuration and select the number of input phases wired to the spa pack. The installer must correctly configure the dip switches to match the pump and power configuration connected to the spa pack. The dip switch bank has…

Spa showing offline

Spa showing offline on SmartLINK app If you spa is suddenly showing as offline on the SmartLINK app, follow the below steps. V1 & V2 modules For V1 or V2 SmartLINK modules firstly run the INFR command. This should force the module to reconnect with your home router. If the INFR command fails to bring…