TYPE setting

TYPE setting The TYPE setting on a SpaNET controller is vital for pump configuration, heating & touchpad functionality. When the TYPE value is set incorrectly it will impact the function of your spa dramatically. Common symptoms are pump buttons functions have changed and are controlling different pumps/blower compared to normal, spa overheating, jet pump running…

SV Series Software (EEPROM) Reset

SV Series Software (EEPROM) Reset The software reset is a good place to start when your spa control begins to behave differently to how you’d expect. Some examples are the temperature displaying in fahrenheit rather than degrees celsius or the heater light not illuminating red when the water temperature is lower than set tetemperature. Performing…

SV Series Heat Pump Not Running

SV Series Heat Pump Not Running No Heat Pump Operation Check SV spa controller settings. Confirm that H.PMP setting has not disabled the heat pump. Check if a heat pump error code is present. The error should scroll across the screen every 30 seconds & the display should show a hammer & spanner symbol Check…

SV Series Heat Pump Error Codes

SV Series Heat Pump Error Codes HEAT PUMP AMB – Ambient temperature sensor error No signal from ambient temperature sensor, or signal is corrupted Check ambient sensor is connected to heat pump pcb Inspect data cable for damage and check data cable connected correctly to SV spa control Disconnect/reconnect data cable from SV spa control…

DIP Switches Explained

DIP Switches Explained Basic spa configuration is achieved by setting dip switches. The dip switches determine pump configuration and select the number of input phases wired to the spa pack. The installer must correctly configure the dip switches to match the pump and power configuration connected to the spa pack. The dip switch bank has…

Spa showing offline

Spa showing offline on SmartLINK app If you spa is suddenly showing as offline on the SmartLINK app, follow the below steps. V1 & V2 modules For V1 or V2 SmartLINK modules firstly run the INFR command. This should force the module to reconnect with your home router V3 SmartLINK Modules For a V3 module…

V3 SmartLINK Wi-Fi MQTT Setup

V3 SmartLINK Wi-Fi MQTT Setup MQTT To enable MQTT you must have our Version 3 SmartLINK Wi-Fi module, with the latest firmware. Press here to learn how to update your V3 SmartLINK module firmware. The MQTT protocol provides a lightweight method of carrying out messaging using a publish/subscribe model. This makes it suitable for Internet…