Setting power save timers – P.SAV
Accessed via the Setup menu Power Save (P.SAV) timers can be set during hours of peak power tariffs to ensure no unnecessary heating or filtration will take place during that time.
The power save setting consists of a choice of; mode, peak power period start time and peak power period end time (refer table below).
Item | Description | Notes |
---|---|---|
P.SAV | Power Save Mode -Functions disabled during peak power periods | OFF = P.SAV disabled (default) LOW = Filtration disabled, allow heating HIGH = Heating disabled, allow filtration |
BGN | Begin Time - Peak power period begins | Adjustable: 00:00 - 23:59 Default = 14:00 (2PM) |
END | End Time - Peak power period ends | Adjustable: 00:00 - 23:59 Default = 20:00 (8PM) |
Accessible options in the setup menu
Menu Item | Setting | Notes |
---|---|---|
MODE | Operating Mode | Normal / Away / Week Modes |
FILT | Hours of filtration per day | 1 to 24 hours |
F.CYC | Filtration cycle blocks | Set filtration to run every 1,2,3,4,6,8,12 or 24 hrs |
SNZE | Sleep time menu | |
1.SNZ | Sleep timer 1 | [1.DAY] Days of week, [1.BGN] Begin Time, [1.END] End Time |
2.SNZ | Sleep timer 2 | [2.DAY] Days of week, [2.BGN] Begin Time, [2.END] End Time |
R.SET | Reset sleep timers | Reset sleep timers to factory defaults |
EXIT | Exit sleep time submenu | |
P.SAV | Power save settings | Off, Low (off-peak filtration), High (off-peak filtration & heating) |
W.CLN | Automatic sanitise time | Daily run time of automatic sanitise cycle (00:00 - 23:59) |
D.DIS | Default display mode | Water Temp (W.TMP), Set Temp (S.TMP) or Clock (TIME) |
T.OUT | Load time out period | Pump / Blower time out period (10 to 60 minutes) |
H.PMP | Heat pump operating mode | Auto (heat or cool) / Heat / Cool / Off (heat pump disabled) |
H.ELE | Heat pump with SV element boost | On = Heat pump + SV element combined for heating Off = Heat pump only |
EXIT | Exit setup menu |
Important Notes
The setup menu item settings are stored in non-volatile memory (EEPROM) and are remembered when power is turned off. No need to reprogram settings when power is restored.
A ten (10) second idle menu time out period exists. If a button press is not detected for 10 seconds, the menu will time out and the screen will return to the default display mode.